0
0
Watch list
was added to the project list.
×

Bollard tubes for BEGA LED system bollards

As car drive-through protection


Bollards are often required to perform extra functions in addition to their actual illumination task. BEGA LED system bollards enable a luminaire head and a luminaire tube to be combined with an additional function. When planning your lighting system, first select a bollard head with the required light distribution. Then choose a matching bollard tube for the additional functions.

These bollard tubes stand on a foundation to be provided by the customer and are set in concrete. They are used as:
• impact protection for cars of 1.5 t · 10 kph
• drive-through protection for cars of 1.5 t · 50 kph

The bollard tube and anchorage unit are designed for two different applications in conjunction with a foundation that must be constructed on site:
1. Impact protection for an impact load of 10 kN according to DIN 1991-1-7 (approximately equivalent to a car of 1.5 tonnes travelling at up to 10 kph)
2. Drive-through protection for a car of max. 1.5 tonnes driving at a speed of up to 50 kph. Certified per PAS 68:2013 British Standard and Europe IWA 14-1:2013.

Finish
  Connection box H
84 016   220 with concrete-casting anchorage unit as drive-through protection 70 632 875

BEGA Library

BEGA Library is a collection of digital publications from Lichtgruppe Gantenbrink. Learn more about our products, discover examples of impressive applications, and watch our high-definition videos.
Learn more

BEGA AR

BEGA AR is pleased to help you assess our luminaires in your own private setting. In a virtual presentation you can place up to five different luminaires simultaneously in any positions you like: in the house, around the house or in the garden. You can then view them from all angles, switching them on and off and even taking photos ofthe various scenes.
Learn more

Electrical safety

The luminaires in this catalogue are designed and produced on the basis of the EN 60598/VDE 0711 standards. The majority of the luminaires bear the relevant test mark on the type plate as well as on the packaging and instructions for use. The other luminaires have been or will be submitted for certification, but the certification and approval procedure is still in progress. We can provide information on the status of the certification procedure at any time. Special orders are produced in accordance with the above set of regulations.
Learn more